Cu-metal-organic framework/multi-walled carbon nanotubes modified glassy carbon electrode for voltammetric determination of anticancer drug calcium folinate

Original scientific paper

Authors

DOI:

https://doi.org/10.5599/admet.3618

Keywords:

Folinic acid, modified electrode, real sample analysis, drug analysis

Abstract

Background and purpose: Maintaining therapeutic efficacy, avoiding toxicity, and ensuring appropriate dosing all depend on accurate calcium folinate (CLF) measurement. Additionally, it is essential for therapeutic drug monitoring, especially for patients undergoing high-dose methotrexate therapy. Experimental approach: We modified the surface of a glassy carbon electrode (GCE) to detect CLF using a Cu-based metal-organic framework integrated with multi-walled carbon nanotubes (Cu-MOF/CNTs). The combined action of CNTs and Cu-MOF significantly enhanced the performance of the GCE surface. Key results: When CLF was quantified by differential pulse voltammetry, the Cu-MOF/CNTs/GCE showed a strong linear response across 0.08 to 450.0 μM. Additionally, the sensing platform demonstrated sensitivity of 0.0879 μA μM-1 toward CLF and a low limit of detection of 0.02 μM. Conclusion:  CLF in actual samples was successfully determined using Cu-MOF/CNTs-modified GCE, showing acceptable efficiency.

Downloads

Download data is not yet available.

References

[1] N. Tubiana-Mathieu, S. Monjanel-Mouterde, C. Lejeune, B. Payet, J. Catalin, Y. Carcassonne, J. Cano. Pharmacokinetics of folinic acid and 5-methyltetrahydrofolic metabolite after repeated oral administration of calcium folinate following methotrexate treatment. European Journal of Cancer 30 (1994) 1281-1284. https://doi.org/10.1016/0959-8049(94)90173-2 DOI: https://doi.org/10.1016/0959-8049(94)90173-2

[2] X. J. Yang, Y. P. Chen, H. C. Wang, J. Zhao, F. Y. Zheng. Protective effect of calcium folinate against methotrexate-induced endosalpinx damage in rats. Fertility and Sterility 95 (2011) 1526-1530. https://doi.org/10.1016/j.fertnstert.2010.08.028 DOI: https://doi.org/10.1016/j.fertnstert.2010.08.028

[3] E. Topuz, M. Basaran, P. Saip, A. Aydiner, A. Argon, B. Sakar, F. Tas, K. Uygun, D. Bugra, N.F. Aykan. Adjuvant intraperitoneal chemotherapy with cisplatinum, mitoxantrone, 5-fluorouracil, and calcium folinate in patients with gastric cancer: a phase II study. American Journal of Clinical Oncology 25 (2002) 619-624. https://doi.org/10.1016/S0959-8049(99)80983-6 DOI: https://doi.org/10.1097/00000421-200212000-00019

[4] J. Yu, X. Liang, Z. Wang, X. Guo, T. Sun, X. Guo. Separation of folinic acid diastereomers in capillary electrophoresis using a new cationic β-cyclodextrin derivative. Plos One 10 (2015) e0120216. https://doi.org/10.1371/journal.pone.0120216 DOI: https://doi.org/10.1371/journal.pone.0120216

[5] G. Francese, F. Corana, O. Meneghetti, F. Marazza. LC–MS characterization of trace impurities contained in calcium folinate. Journal of Pharmaceutical and Biomedical Analysis 39 (2005) 757-763. https://doi.org/10.1016/j.jpba.2005.04.014 DOI: https://doi.org/10.1016/j.jpba.2005.04.014

[6] I. D. Merás, A. Espinosa-Mansilla, M.J. Gómez, F. S. López. Kinetic fluorimetric study of the oxidation reaction of folinic acid (leucovorin) with potassium permanganate. Determination in human urine. Talanta 55 (2001) 623-630. https://doi.org/10.1016/S0039-9140(01)00472-6 DOI: https://doi.org/10.1016/S0039-9140(01)00472-6

[7] Z. Zhu, F. Wang, F. Wang, L. Xi. Simultaneous determination of methotrexate and calcium folinate with electrochemical method based on a poly-ABSA/functionalized MWNTs composite film modified electrode. Journal of Electroanalytical Chemistry 708 (2013) 13-19. https://doi.org/10.1016/j.jelechem.2013.09.004 DOI: https://doi.org/10.1016/j.jelechem.2013.09.004

[8] O. A. Sadik, A. O. Aluoch, A. Zhou. Status of biomolecular recognition using electrochemical techniques. Biosensors and Bioelectronics 24 (2009) 2749-2765. https://doi.org/10.1016/j.bios.2008.10.003 DOI: https://doi.org/10.1016/j.bios.2008.10.003

[9] W. A. Yue-Rong, H. U. Ping, L. U. Guo-An, W. A. Yi-Ming. Application of carbon nanotube modified electrode in bioelectroanalysis. Chinese Journal of Analytical Chemistry 36 (2008) 1011-1016. https://doi.org/10.1016/S1872-2040(08)60052-3 DOI: https://doi.org/10.1016/S1872-2040(08)60052-3

[10] M. Opallo, A. Lesniewski. A review on electrodes modified with ionic liquids. Journal of Electroanalytical Chemistry 656 (2011) 2-16. https://doi.org/10.1016/j.jelechem.2011.01.008 DOI: https://doi.org/10.1016/j.jelechem.2011.01.008

[11] W. E. Van der Linden, J. W. Dieker, Glassy carbon as electrode material in electro-analytical chemistry. Analytica Chimica Acta 119 (1980) 1-24. https://doi.org/10.1016/S0003-2670(00)00025-8 DOI: https://doi.org/10.1016/S0003-2670(00)00025-8

[12] P. Lakhera, V. Chaudhary, A. Jha, R. Singh, P. Kush, P. Kumar. Recent developments and fabrication of the different electrochemical biosensors based on modified screen printed and glassy carbon electrodes for the early diagnosis of diverse breast cancer biomarkers. Materials Today Chemistry 26 (2022) 101129. https://doi.org/10.1016/j.mtchem.2022.101129 DOI: https://doi.org/10.1016/j.mtchem.2022.101129

[13] Z. Zhang, Y. Lou, C. Guo, Q. Jia, Y. Song, J. Y. Tian, S. Zhang, M. Wang, L. He, M. Du. Metal–organic frameworks (MOFs) based chemosensors/biosensors for analysis of food contaminants. Trends in Food Science & Technology 118 (2021) 569-588. https://doi.org/10.1016/j.tifs.2021.10.024 DOI: https://doi.org/10.1016/j.tifs.2021.10.024

[14] N. Ma, A. Wei, H. Peng, L. Xie, Y. Jin, Z. Yin, G. Li. A chiral electrochemical sensor based on β-CD/Ce-doped Cu-MOF/MWCNTs-COOH for enantioselective recognition and detection of levofloxacin. Analytica Chimica Acta 1420 (2026) 345964. https://doi.org/10.1016/j.aca.2026.345964 DOI: https://doi.org/10.1016/j.aca.2026.345964

[15] L.X. Xia, T.T. Liu, S.T. Zhang, W.Y. Pei, J.F. Ma. Electrochemical determination of trace Cu (II) and Pb (II) with a new sensor constructed by a composite of cyclotriguaiacylene MOF/MWCNT-COOH. Journal of Molecular Structure 1378 (2026) 147217. https://doi.org/10.1016/j.molstruc.2026.147217 DOI: https://doi.org/10.1016/j.molstruc.2026.147217

[16] G.M. Jaid, A.A. AbdulRazak, M. al-Shaeli, Q.F. Alsalhy, R.A. Al-Juboori.Plastic waste-based Cu-BDC and COOH-MWCNT@ Cu-BDC MOF for enhancing PPSU membrane for efficient heavy metal removal from industrial wastewater. Journal of Environmental Chemical Engineering 14 (2025) 120608. https://doi.org/10.1016/j.jece.2025.120608. DOI: https://doi.org/10.1016/j.jece.2025.120608

[17] R. Sakthivel, L.Y. Lin, Y.F. Duann, H.H. Chen, C. Su, X. Liu, J.H. He, R.J. Chung. MOF-derived Cu-BTC nanowire-embedded 2D leaf-like structured ZIF composite-based aptamer sensors for real-time in vivo insulin monitoring. ACS Applied Materials & Interfaces 14 (2022) 28639-28650. https://doi.org/10.1021/acsami.2c06785 DOI: https://doi.org/10.1021/acsami.2c06785

Downloads

Published

26-10-2026

Issue

Section

Medicinal chemistry

How to Cite

Cu-metal-organic framework/multi-walled carbon nanotubes modified glassy carbon electrode for voltammetric determination of anticancer drug calcium folinate: Original scientific paper. (2026). ADMET and DMPK, 14, Article 3618. https://doi.org/10.5599/admet.3618