Surfactant modified carbon nanotube paste electrode for the sensitive determination of mitoxantrone anticancer drug

Authors

  • Jamballi G. Manjunatha Department of Chemistry, FMKMC College, Madikeri, Mangalore University Constituent College, Karnataka

DOI:

https://doi.org/10.5599/jese.368

Keywords:

Electrochemical sensors, MTX determination, carbon nanotubes, surfactant modified electrodes

Abstract

Surfactant modified carbon nanotube paste electrode is prepared as electrochemical sensor with high sensitivity in responding to Mitoxantrone (MTX). Electrochemical oxidation of MTX is investigated in buffered solution by cyclic voltammetry that is found very sensitive method for detection of MTX. It is shown that the sodium dodecyl sulfate modified carbon nanotube paste electrode (SDSMCNTPE) gives enhanced current response for MTX compared to the bare carbon nanotube paste electrode (BCNTPE). Different parameters were tested to optimize the conditions for MTX determination. The effects of different surfactant and surfactant concentration, pH, scan rate, detection limit (LOD), limit of quantification (LOQ) and concentration of MTX on the oxidation peak current values were determined. Excellent results were obtained by cyclic voltammetry using SDSMCNTPE, where two MTX oxidation peaks appeared at 367 and 596 mV vs. SCE. Detailed analysis of the second voltammetric peak showed the linear dynamic range between 2×10−7 and 7×10−6 M MTX with the slope of co-relation coefficient of 0.99271. LOD and LOQ were determined as 3.5 ×10−8 M and 11×10−8 M, respectively. The SDSMCNTPE showed very good reproducibility, high stability in its voltammetric response, high electrochemical sensitivity and low detection limit for MTX.

Downloads

Download data is not yet available.

References

C. E. Myers, E. G. Mimnaugh, G. C. Yeh, B. K. Sinha, Anthracycline and anthracenedione-based anticancer agents, J. W. Lown (ed.), Elsevier, Amsterdam, The Netherlands, 1988, p. 527.

K. Reszka, P. Kolodziejczyk, J.W. Lown, Journal of Free Radicals in Biology and Medicine, 2 (1986) 2532.

C. Wu, P. Guo, H. Song, Hua Xi Yi Ke Da Xue Xue Bao 21 (1990) 3941. (in Chinese)

J. L. Johnson, A. Ahmad, S. Khan, Y. F. Wang, A.W. Abu-Qare, J. E. Ayoub, A. Zhang, I. Ahmad, Journal of Chromatography B 799 (2004) 149155.

S. M. Golabi, V. Hassan Zadeh, Talanta 43 (1996) 397406.

J. B. Hu, Q. L. Li, Chemical Journal of Chinese Universities 22 (2001) 380384.

J. C. C. Villar, A. C. García, P. T. Blanco, Journal of Pharmaceutical and Biomedical Analysis 10 (1992) 263–267.

P. V. Venkatesan, B. Nagarajan, Journal of Clinical Biochemistry and Nutrition 19 (1995) 123130.

G. Nicolau, V. Szucs-Myers, W. McWilliams, J. Morrison, A. Lanzilotti, Investigational New Drugs 3 (1985) 5156.

D. G. Nordblom, A. L. Pachla, T. Chang, R. L. Whitfield, H. D. H. Showalter, Cancer Research 49 (1989) 5345-5351.

A. Erdem, M. Ozsoz, Turkish Journal of Chemistry 25 (2001) 469475.

J. Wang, M. Musameh, Analytical Chemistry 75 (2003) 2075–2079.

Y. Lin, F. Lu, Y. Tu, Z. Ren, Nano Letters 4 (2004) 191–195.

Y. Liu, L.J. Huang, S.J. Dong, Biosensors and Bioelectronics 23 (2007) 35–41.

J. M. Nugent, K.S.V. Santhanam, A. Rubio, P. M. Ajayan, Nano Letters 1 (2001) 87–91.

A. Merkoci, Microchimica Acta 152 (2006) 157–174.

J. F. Rusling, Accounts of Chemical Research 24 (1991) 7581.

E. Michaelis, D. Wohrle, J. Rathousky, M. Wark, Thin Solid Films 497 (2006) 163169.

J. F. Rusling, Accounts of Chemical Research 31 (1998) 363369.

S.M. Chen, W.Y. Chzo, Journal of Electroanalytical Chemistry 587 (2006) 226234.

J. G. Manjunatha, B. E. Kumara Swamy, R. Deepa, V. Krishna, G. P. Mamatha, U. Chandra, International Journal of Electrochemical Science 4 (2009) 662667.

J. G. Manjunatha, B.E. Kumara Swamy, G.P. Mamatha, S. Sharath Shankar, O. Gilbert, B. N. Chandrashekar, International Journal of Electrochemical Science 4 (2009) 14691478.

J. G. Manjunatha, B.E. Kumara Swamy, G.P. Mamatha, O. Gilbert, M. T. Shreenivas, B. S. Sherigara, International Journal of Electrochemical Science 4 (2009) 17061718.

B. Hoyer, N. Jensen, Electrochemistry Communications 8 (2006) 323–328.

H. Chengguo, H. Shengshui, Electrochimica Acta 49 (2004) 405412.

J. M. Shweta, P. S. Nagaraj, T. S. Nandibewoor, Colloids and Surfaces B: Biointerfaces 97 (2012) 16.

J. G. Manjunatha, B. E. Kumara Swamy, G. P. Mamatha, U. Chandra, E. Niranjana B. S. Sherigara, International Journal of Electrochemical Science 4 (2009) 18796.

H. Beitollahi, J.-B. Raoof, R. Hosseinzadeh, Analytical Sciences 27 (2011) 991–997.

H. Beitollahi, J.-B. Raoof, R. Hosseinzadeh, Electroanalysis 23 (2011) 1934–1940.

H. Beitollahi, M. Ali Taher, M. Ahmadipour, R. Hosseinzadeh, Measurement 47 (2014) 770–776.

M. E. Swartz, I. S. Krull, Analytical method development and validation, Marcel Dekker, New York, USA, 1997.

B. Hong, Q. Chen, Advances in Chemical Engineering and Science, 2 (2012) 453460.

A. M. O. Brett, T. R. A. Macedo, D. Raimundo, M. H. Marques, S. H. P. Serrano, Analytica Chimica Acta 385 (1999) 401408.

Published

31-03-2017

How to Cite

Manjunatha, J. G. (2017). Surfactant modified carbon nanotube paste electrode for the sensitive determination of mitoxantrone anticancer drug. Journal of Electrochemical Science and Engineering, 7(1), 39–49. https://doi.org/10.5599/jese.368

Issue

Section

Electrochemical Science

Most read articles by the same author(s)