J. Electrochem. Sci. Eng.  

Electrochemical behaviour and voltammetric determination of p-phenylenediamine at carbon paste electrode

Abdelaziz Ait Sidi Mou, Aicha Ouarzane, Mama El Rhazi

Abstract


An electrochemical method was developed for voltammetric determination of p-phenylenediamine using a carbon paste electrode (CPE). The electrode exhibited the highest electrocatalytic activity toward oxidation and reduction of p-phenylenediamine in the phosphate buffer, pH 7 solution. After optimizing the experimental conditions and square wave voltammetry parameters, a linear current response toward concentration of p-phenylenediamine was obtained in the range of 0.12–3.00 µM with detection limit of 0.071 µM. The proposed procedure was successfully applied for determination of the total p-phenylenediamine content in the takeout extract sample.


Keywords


p-phenylenediamine; Eeectroanalysis; voltammetry

Full Text:

PDF (1,197 kB)

References


A. Ababou, K. Ababou, A. Mosadik, C. Lazreq, A. Sbihi, Annales Françaises d'Anesthésie et de Réanimation 19 (2000) 105-107.

I. J. Kang, M. H. Lee, Contact dermatitis 55 (2006) 26–29.

C. Mascres, J. Gaeton, L'union Medicale Du Canada 103 (1974) 672-677.

K. S. Chugh, G. H. Malik, P. C. Singhal, Journal of Medicine 13 (1982) 131-137.

A. Filali, I. Semlali, V. Ottaviano, C. Furnari, D. Corradini, R. Soulaymani, African Journal of Traditional, Complementary and Alternative Medicine 3 (2006) 142–149.

S. Motaouakkil, B. Charra, A. Hachimi, H. Ezzouine, H. Guedari, H. Nejmi, A. Benslama, Annales Françaises d'Anesthésie et de Réanimation 25 (2006) 708–713.

M. Abdelraheem, M. Hamdouk, E. E. Zijlstra, Arab Journal of Nephrology and Transplantation 3(1) (2010) 39-43.

N. Habti, G. Benzakour, Y. Zaid, A. Naya, N. Nourichafi, H. Mifdal, S. Motaouakkil, M. Oudghiri, Journal of Toxicology and Environmental Health Sciences 2(7) (2010) 101-107.

A.Stambouli, M. A. Bellimam, N. El Karni, T. Bouayoun, A. El Bouri, Forensic Science International 146S (2004) S87–S92.

M. L. Di Gioia, A. Leggio, A. Le Pera, A. Liguori, A. Napoli, F. Perri, C. Siciliano, Journal of Chromatography A 1066 (2005) 143–148.

S. Madi-Jebara, G. Sleilaty, A. Yazigi, Annales Françaises d'Anesthésie et de Réanimation 25 (2006) 902–910.

A. Geto, M. Pita, A. L. De Lacey, M. Tessema, S. Admassie, Sensors and Actuators B 183 (2013) 96– 101.

V. K. Gupta, M. L. Yola, N. Atar, Z. Ustundag, A. O. Solak, Electrochimica Acta 112 (2013) 541– 548.

L. Zhang, Z. Shi, Q. Lang, J. Pan, Electrochimica Acta 55(3) (2010) 641–647.

I. Adraoui, M. El Rhazi, A. Amine, L. Idrissi, A. Curulli, G. Palleschi, Electroanalysis 17(8) (2005) 685-693.

A. Madhankumar, N. Rajendran, Synthetic Metals 162 (2012) 176– 185.

B. Lakard, G. Herlem, S. Lakard, B. Fahys, Journal of Molecular Structure: THEOCHEM 638 (2003) 177–187.

M. Rani, R. Ramachandran, S. Kabilan, Synthetic Metals 160 (2010) 678–684.

J. Li, J. Chen, X. L. Zhang, C. H. Lu, H. H. Yang, Talanta 83 (2010) 553–558.

M. H. Parvin, Electrochemistry Communications 13 (2011) 366–369.

X. Kang, J. Wang, H. Wu, J. Liu, I. A. Aksay, Y. Lin, Talanta 81 (2010) 754–759.

M. Chao, X. Ma, X. Li, International Journal of Electrochemcal Science 7 (2012) 2201– 2213.

S. A. da França, M. F. Dario, V. B. Esteves, A. R. Baby, M. V. R. Velasco, Journal of Cosmetics 2 (2015) 110-126.

Q. Zheng, P. Yang, H. Xu, J. Liu, L. Jin, Journal of Environmental Sciences 24(9) (2012) 1717–1722.




DOI: http://dx.doi.org/10.5599/jese.386

Refbacks

  • There are currently no refbacks.




jESE : : Open Access Journal  :  : ISSN 1847-9286